Three-core Copper 3.6-6KV Cross-linked Polyethylene Insulated Non-magnetic Metal Strip Armored PE Sheathed Power Cable
Brand SHANGSHANG
Certification N/A
Lead Time 15days
Guarantee Period 12months
Source of Supply Jiangsu
Payment Method T/T L/C
Cross-linked PE insulation refers to a process that a chemical method or physical method is used to convert linear structure of PE into three-dimensional network structure, that is, thermoplastic PE is converted to thermoset cross-linked PE, so as to greatly improve its mechanical performance, heat aging resistance, environmental stress resistance and excellent electrical performance. Cross-linked PE insulated cable conductor has a normal operating temperature of 90℃ and has features including simple structure, small outer diameter, light weight, convenient use and no restrictions on laying height difference. It is generally laid overhead, indoors, in tunnels, in cable trenches and pipelines.
Technical Parameters:
1. The product is applicable to medium and high voltage power transmission and distribution system with rated voltage as 3.6/6~26/35kV. 2. The highest rated temperature of cable conductor is 90℃. 3. The highest temperature of short circuited (lasting for maximum 5s) cable conductor shall not exceed 250℃. If the temperature is lower than 0℃, the cable conductor should be preheated first. 4. Minimum bending radius of cable in installation: unarmored single-core cable 20D, unarmored three-core cable 15D, armored single-core cable 15D, armored three-core cable 12D.
Recommendations
Pumping Unit
BrandZYZJ
Inspection Mirror
BrandENDURA
Single-core Copper 21/35KV Cross-linked Polyethylene Insulated Thin Steel Wire Armored PVC Sheathed Power Cable
BrandWANDA
Packing Assembly, P/N:RS78.120-00 |SL450/SL450A
BrandRUSHI
FX Series Non-Rotary Stabilizer│HF1000│HF2000│HF3000│HF4000
BrandSHUANGJIA
Explosion-proof LED Emergency Floodlight
BrandOKTECH
Bearing 6220, P/N: W21106220| LW450×1000-N
BrandXBSY
Pumping Unit
BrandZYZJ
Flame-proof Emergency HESE Lamp
BrandZM
Power Tong Accessories | Griping Cylinder, P/N:01.04.00M |ZQ203-100
BrandRUSHI
Quick Change Folding Lock-Back Utility Knife
BrandSHEFFIELD
Float Valve Core|Model"F"|Model"G"
BrandSHUANGJIA
Lower Sealing Sleeve, P/N:RS78.120-12 |SL450/SL450A
BrandRUSHI
107.37.01.13 Gasket
BrandLS
PA-4073 Baseboard Installation Thermistor and Thermocouple Isolator (Two-in Two-out)
BrandParagon
Copper Single-core Rated Voltage 6/10KV Cross-linked PE Insulated Sheathed Power Cable
BrandWANDA
SW Series Explosion-proof Lighting Switch
BrandEEW
PA-4112 Guide Rail Installation Switch Quantity Signal Isolator (Two-in Two-out)
BrandParagon