Flame Retardant Antistatic Explosive Proof Intelligent Thermal Suit (Vest)
Brand KANGSHIELD
Certification N/A
Lead Time 30days
Guarantee Period 6months
Source of Supply Shandong
Payment Method T/T L/C
This type of Thermal Suit which adopts Dupont FR Antistatic fabrics with intrinsical flame retardant and conducting static function is applicable to industries such as petrochemical and gas liquidation etc.
Background:
The occupational health protection for outdoor staff in the cold region remains at the level of passive warm retention and effective active heating solution is still not available. The existing thermal suit comprised of carbon fiber, low voltage resisting wire can not be applicable to operation in the cold environment because of the defects of lower heating temperature and failure in controlling temperature.
Space Grade exothermal materials (temperature memory intelligent semiconductor materials) is used as heating element and low voltage portable module (7.4V/5V) is used as power supply. Intelligent materials can be exothermal to (80—110℃) under low voltage and provide high active heating and create a 45—90℃ internal circulating warm environment within the thermal suit and It can be continuously used for 4-6 hours per charge to settle down the problem of not hot for existing thermal suit in the market and also be essential for occupational health protection for outdoor staff in the cold region and first choice for outdoor active heating.
Having adopted unique military industrial protective design, thermal suit has adjusting functions fitting for length and fat or thin and can be adaptable to different close body figure’s use! Heating plates placed on belly and back make body nice and warm.
Operation Principle
Temperature memory semiconductor material itself possessing with physical properties of temperature measurement, temperature controlling and heating adopted by thermal suit is one kind of self-control temperature heating element. The materials can sense the environmental temperature change and also offer corresponding treatment to temperature change and conduct analysis, judgement and response to increase or decrease resistance, thus developed heating products are provided with energy saving property via variable power and higher reliability via contactless temperature control and high safety advantage;
Thermal suits features are as follows:
1) Low voltage High temperature exothermal technology
2) Frequency Conversion Heating and intelligent exothermal and longer service time;
3) Multiple point exothermal get body warm;
4) Intelligent Heating material formula can be adjusted according to specific demand to produce the different heating materials with different switch temperature to meet service requirements under different environments and conditions.
5) Provided with hot compress etc physical therapy, it can offer staff in lower temperature environment therapy at any time;
6) Battery powered and lower voltage operation are harmless to human body.
Differentiation Advantage
1. High Magnification Thermal Technology
High temperature can be obtained through portable power supply and 45—90℃ internal warm environment is created with surging heat. 105-115℃ can be reached under low voltage 5-7.4V exceeding two times of other products;
2. Self-Constant Temperature Technology
Possessing with self-constant controlling temperature capacity, new material with innovative technology, can self-control temperature to keep constant temperature through increasing or decreasing the resistance, more intelligent than other materials;
3. Leading energy saving technology
New materials will adjust power according to the itself-energy absorbed speed, materials will be breathing type heated and it’s power will depend on heat loss, rate, If having entered into warm environment, materials will decrease the power automatically and more energy saving comparing to other materials;
4. Super safe Temperature switch technology
With the highest temperature protection character, material eradicates fire etc potential safety risks, Being provided with ceiling temperature, if materials temperature reach the preset temperature memory point and resistance will increase infinite to cut off the circuit and more safer fundamentally comparing to other materials.
Thermal Suit Structural Design
1. Super Heating System: As the core layer, temperature memory intelligent heating material is overlaid with super aluminum radiating layer can make the heat energy output gushingly;
2. Special Thermal Insulation System: HEAT thermal reflection layer+ Super silk cotton insulation layer+ Leakage proof layer+ Special cotton insulation layer, four level insulation layer will keep the heat longer and give full play to variable power of intelligent material;
3. Dual Thermoregulation System: Hi-energy Lithium Battery Output power shift gear + material self-regulating power function, dual thermoregulation system built the automatic constant temperature system within thermal suit;
Military Industrial special self-adaption physical design: Unique military industrial protective equipment design let the thermal suit fit different figure with different height, fat and thin. Scientifical ergonomic design let the warm surround the whole body, Thermal suit close to body completely and can conduct the heat into body steadily and bring you warmth next to the skin.
Use Features
Ground-breaking application of New materials+New Heating structure+power converting circuit let the project possessing innovation and novelty:
Based on Temperature Memory Thermal Semi-conductor Heat Sensitive Material researched and developed independently relevant heating series products are also developed to fill the vacancy at home and abroad. Since company self developed low voltage semiconductor is adopted, thermal suit can work under the low voltage from 5 to 7.4V and be hi-temperature exothermal and settle down issues of not hot and eradicate the fire risk for all kinds of thermal suits and get them possessing real use value:
1) Against thermal suit essential issues of not enough exothermal temperature subject to lower voltage;
2) Against thermal suit safety issues caused by local heat storage;
3) Against thermal suit issues of unavailable energy saving;
4) Against thermal suit issues of controlling temperature ineffectively;
5) Against existing thermal suit issues of extinction of heating efficiency;
Cautions
1. The Thermal suit with higher heating temperature is specially designed for the outdoor staff who are working in the cold environment, Heating temperature should be noticed while it is dressed in, if the temperature is higher, please decrease the battery power or put on more underwear or will be lower temperature burnt;
2. The heating liner will be connected with thermal suit through Velcro and heating liner can be assembled or disassembled freely against customer’s demand for washing and cleaning conveniently. Heating liner including heating elements is prohibited to be water washed or dry cleaned and can be wiped off via little moist cloth and hung up for short time; thermal suit liner can not be disassembled by yourself.
3. Careful examining products should be performed before application every time, if any wear or damages or other problems are found, please stop immediately application and contact with sales representatives.
4. Since the thermal plate is put into the liner of thermal suit and if the thermal suit is required to be washed and please take out the thermal plates before washing. Enhanced type or basic type thermal suit are prohibited to be water washed or be dry cleaned or be curlating.
5. Since there are some thermal plates or wires in the thermal suit liner and please do not lay them at will while the thermal suit is not in service and please well fold up and put it into multifunctional storage case and do not fold up the thermal plates;
6. Heavy weight or hard object should be permitted to press the thermal plate to avoid destroy the heating elements in the thermal plate;
7. Special power charger should be employed and if the other charger is used and it will destroy the portable power supply or cause overcharged and further destroy the battery; Special battery for thermal suit should be used or we will not be responsible for the any problems caused herein.
8. Application of thermal suit is prohibited during the sleeping to avoid to be gotten a burn.
9. Care should be taken that application should be stopped immediately once there is red or swollen on skin or other uncomfortable reactivity because of heating temperature higher than the shell temperature for long time.
Arc Protective Explosive Proof Intelligent Thermal Suit (Vest Type): This type of Thermal Suit which adopts arc protective fabrics and completed with explosive proof battery is applicable to application in hot-line work within operation situation with combustible gas and outdoor electrical operation;
Explosive Proof Type Thermal Suit
Three explosive proof measures for thermal suit ensure the safety
Having adopted three explosive proof type, explosive proof type thermal suit ensure it’s application in the hazardous locations.
1) Intrinsic safety type Circuit design:
The electronic regulation and control circuit is designed to intrinsic safety circuit, namely, circuit itself is intrinsic safety and applicable to all hazardous locations.
2) Set up explosion isolation measure:
A explosion isolation case is added to the Battery to ensure battery running safely.
3) Encapsulation process to be performed:
The components produced potentially arc, spark or high temperature to ignite the explosive mixture within the thermal suit should be encapsulated to prevent these electrical components contacting with explosive mixture.
Technical Parameters:
Fabrics: 200g Dupont Nomex IIIA, 120g Dupont 50/50 FR Lining, filling is 3m 100g Thinsulate, YKK Nylon Zipper, FR velcro; Four pieces of thermal energy plate,7.4V/6000mAh polymer lithium battery with explosive proof enclosure
Recommendations
Pen Light With 2AA
BrandENDURA
Crosshead Pin, P/N: RS11309.04.011 | RS F-1300/RS F-1600
BrandKERUI
Power Tong Accessories | Quick Release Valve, P/N: QF514C | ZQ203-100
BrandRUSHI
Power Tong Accessories | Planet Gear Shaft, P/N: 56.330.04 | TQ340-35
BrandRUSHI
Bearing 6016, P/N: GB/T276| LW450×1000-N
BrandXBSY
Steel Car Seat 440x360x365mm
BrandENDURA
Cyliner Head Plug, P/N: AH100101050500 |BOMCO F-800/ F-1000
BrandKERUI
Snap In Tire Valve Installer
BrandENDURA
Bonded V-Belt, 4ZV25J, 5ZV25J | For Mud Pump Drive
BrandXLFT
Hand Riveter
BrandENDURA
Central Pipe, P/N: RS78.100-12A | SL450
BrandRUSHI
25pcs. VDE Insulated Tools Set
BrandENDURA
SYD Series Cup Tester
BrandSHUANGJIA
VDE Cable Knives
BrandENDURA
Upper Guide Plate, P/N: AH1001010402, AH33001-04.02 | BOMCO F-1000
BrandKERUI
HJ Series H Safety Joint
BrandSHUANGJIA
ZT-3VS Electric Vertical Take-off and Landing Fixed-Wing UAV
Brandaeronitor
Power Tong Accessories | Locating Handle, P/N: 01.01.01.00M | ZQ162-50, ZQ203-100
BrandRUSHI